KONGRA LLC · Commercial ventilation

Commercial Kitchen Exhaust Fan Repair

Diagnostics for roof-mounted centrifugal upblast exhaust fans used over restaurant and commercial-kitchen hoods — including no-start, weak airflow, vibration, belt, bearing, motor and grease-related concerns.

Independent service by KONGRA LLC. We are not affiliated with or authorized by the manufacturers named on this site. Model coverage, service scope and visit fees are confirmed before an appointment.

Common symptoms

Rooftop exhaust fan problems we diagnose

Fan will not start
Weak exhaust / poor airflow
Excessive vibration or noise
Belt wear / pulley misalignment
Motor overheating or tripping
Wheel buildup or imbalance
Bearing noise
Grease trap or drain overflow
Real KONGRA field work

Roof-mounted upblast fan documented on site

Roof-mounted centrifugal upblast commercial kitchen exhaust fan documented during KONGRA field service
Field equipment documented by KONGRA. The manufacturer and exact model were not readable from the available nameplate, so no brand is inferred from appearance.

This installation is a roof-mounted centrifugal upblast fan serving a commercial-kitchen ventilation system. Before parts are selected, the service visit confirms the fan nameplate, direct- or belt-drive arrangement, motor data, rotation, wheel condition and the relationship between the hood, duct and roof fan.

Identify the exact fan and drive type
Measure airflow symptoms before assuming a motor fault
Inspect wheel buildup, vibration and bearings
Check belt, pulley and grease-management condition where fitted
Manual-backed service themes

What the major upblast-fan manuals emphasize

Wheel & airflow

Greenheck's CUE/CUBE manual warns that reversed rotation reduces airflow and can overload the motor. It also notes that dirt or grease buildup on the wheel can create imbalance, vibration and unsafe operation.

Belts, pulleys & bearings

Belt-drive units require periodic belt wear, tension and pulley-alignment checks. Misaligned pulleys can cause belt wear, vibration, noise and power loss; bearing lubrication intervals depend on duty and environment.

Grease management

Restaurant upblast fans require regular cleaning and grease-receptacle maintenance. Grease accumulation can affect balance and also create roof and fire-safety concerns, so fan maintenance is coordinated with hood-cleaning requirements.

Technical references

Equipment-class manuals

Independent service

Independent service. Brand names identify equipment serviced.

Related commercial services

FAQ

Frequently asked questions

Do you service rooftop restaurant exhaust fans?+

KONGRA can evaluate selected roof-mounted centrifugal upblast exhaust fans and related controls. Exact model and service scope are confirmed from the fan nameplate before parts are ordered.

Why is a kitchen exhaust fan vibrating?+

Common causes include wheel buildup or imbalance, belt and pulley problems on belt-drive units, loose fasteners, worn bearings or wheel contact. The cause is confirmed by inspection rather than assumed from the noise alone.

Is the fan in the field photo a confirmed Greenheck or CaptiveAire model?+

No. The photo documents a roof-mounted upblast fan, but the manufacturer data plate is not readable enough to identify the exact brand or model. Greenheck and CaptiveAire manuals are used here only as equipment-class references.